BGYBL - MIL-C-22750 COLOR 17875 A, PRODUCTCODE 111-075A (PART B)

  • MSDS: BGYBL
  • Manufacturer: D J SIMPSON COMPANY
  • Product Name: MIL-C-22750 COLOR 17875 A, PRODUCTCODE 111-075A (PART B)
  • National Stock Number: 8010-00N010847
Product Identification

Product ID:MIL-C-22750 COLOR 17875 A, PRODUCTCODE 111-075A (PART B)
MSDS Date:03/28/1989
FSC:8010
NIIN:00N010847
MSDS Number: BGYBL

Responsible Party
D. J. SIMPSON COMPANY
111 SOUTH MAPLE AVENUE
SOUTH SAN FRANCISCO, CA 94080

Emergency Phone: 415-873-5990

Info Phone: 415-873-5990

Cage: HO614

Contractor
SIMPSON D J CO INC
2265 SOUTH SAN FRANCISCO, CA 94080-6303 US

Telephone: 415-873-5990

Cage: 33244

Ingredients

AROMATIC HYDROCARBON

CAS: 64742-95-6

Fraction By Weight: 20%

OSHA PEL N/K

ACGIH TLV: N/K


ETHYLENE GLYCOL MONOPROPYL ETHER

CAS: 2807-30-9

RTECS: KM2800000

Fraction By Weight: 9%

OSHA PEL N/K

ACGIH TLV: N/K


TOLUENE (SARA III)

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: 7%

OSHA PEL 200 PPM/150 STEL

ACGIH TLV: 50 PPM; 9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


N-BUTYL ALCOHOL (SARA III)

CAS: 71-36-3

RTECS: EO1400000

Fraction By Weight: < 5.0%

OSHA PEL 100 PPM

ACGIH TLV: S, C 50 PPM; 9293

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


4.28 LB/GL (513 G/L) PER MDR'S MSDS

RTECS: 9999999VO

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:N/K
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: ANESTHETIC. IRRIT OF RESP
TRACT W/ HDCH, NAUSEA, DIZZY, UNCONSCIOUSNESS OR COMA. INGEST OR
SUBSEQUENT VOMITING CAN RESULT IN ASPIRATION OF LIGHT HYDROCARBON
LIQUID INTO THE LUNGS WHICH CAN CAUSE FATAL PNEUMONITIS.
REPEATED/PROLONGED OVEREXPOSURE TO SOLVENTS MAY LEAD TOPERMANENT
BRAIN OR NERVOUS SYSTEM DAMAGE
Explanation of Carcinogenicity:THIS PROD CONTAINS ONE OR MORE CHEM
KNOWN TO THE STATE OF CA TO CAUSE CANCER, BIRTH DEFECTS OR OTHER
REPRO HARM (MFR).
Effects of Overexposure:INHAL: DIZZY, NAUSEA, HDACH, IRRIT OF THE RESP
TRACT, UNCON AND EVEN ASPHYXIATION AT HIGH CONC. SKIN CONTACT:
IRRITATION, DRY OR CRACKING. EYE: IRRIT OR EYE BURN. INGEST:
DIZZINESS, NAUSEA. NOT EXPECT ED TO HAVE ACUTE SYSTEMIC TOXICITY BY
INGESTION. SKIN ABSORPTION: SEVER IRRITATION OR BURNING SENSATION
(SEE SUP DATA)
Medical Cond Aggravated by Exposure:PREEXISTING LUNG, HEART, LIVER,
KIDNEY AND SKIN DISORDERS

First Aid

First Aid:INHAL: REMOVE FROM EXPOS, RESTORE BREATH.ADMIN O*2 IF NEEDED,
SEEK MED HELP IMMEDIATELY. EYE: FLUSH W/ LARGE AMOUNTS OF H*2O FOR
15 MIN W/ EYELIDS OPEN. SEEK A PHYSICIAN IMMEDIATELY. SKIN: WASH W/
SOA P AND WATER. REMOVE CONTAMINATED CLOTHING INGESTION: DO NOT
INDUCE VOMITING. DRINK ONE OR TWO GLASSES OF WATER TO DILUTE. SEEK
MEDICAL HELP IMMEDIATELY. KEEP PATIENT QUIET, WARM AND COMFORTABLE.

Fire Fighting

Flash Point Method:TCC
Flash Point:45 F; 7.22 C
Lower Limits:11.2
Upper Limits:1.0
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICAL, WATER FOG
Fire Fighting Procedures:FULL PROT EQUIP INCLUDING SCBA. FIGHT
ASVOLATILE LIQUID FIRE. USE H*2O TO COOL FIRE EXPOSED CONTRS. AVOID
SPREAD FIRE W/COOLING H*20. FOG NOZZLE RECOMMENDED.
Unusual Fire/Explosion Hazard:CLOSED CONTR MAY EXPLODE WHEN EXPOSED
TOEXTREME HEAT. VAPORS MAY TRAVEL TO SOURCES OF IGNITION AND CAUSE
A FLASH FIRE. ISOLATE FROM ALL SOURCES OF (SUP DATA)

Accidental Release

Spill Release Procedures:VENTILATE AREA. REMOVE ALL SOURCES OF
IGNITION. CONTAIN AND REMOVE WITH INERT ABSORBENT AND NON-SPARKING
TOOLS. WEAR PROTECTIVE EQUIPMENT DURING CLEANUP. CONTAIN LIQUID TO
PREVENT CONTAMINATION OF SOI L AND GROUND WATER.
Neutralizing Agent:N/K

Handling

Handling and Storage Precautions:KEEP CLOSURE TIGHT + CONTR IN UPRIGHT
POSN. STORE AWAY FROM HEAT OR OTHER SOURCEOF IGNITION. GROUND CONTR
OR BOND DURINGLIQUID XFR. HANDLE (SUP DATA)
Other Precautions:AVOID PROLONG BRTH OF VAPOR, SKIN OR EYECONT. EMPTY
CONTR MAY STILL CONTAIN HAZ OR FLAME MAT; OBS MSDS WHEN HANDLE.
TOLUENE, CAN CAUSE IRREVERSIBLE CHANGE IN GENETIC MAT. BENZENE, A
CANCER CAUSE HYDRO CARB IMPURITY OF PETRO PROD (SEE PART A)

Exposure Controls

Respiratory Protection:APPROVED CHEMICAL MECHANICAL FILTER RESPIRATOR
(MFR). NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF
CONCERN.
Ventilation:REQUIRED, 200 CFM MINIMUM (MFR). CONSULTLOCAL SAFETY/HEALTH
AUTHORITIES IF ADDITIONAL GUIDANCE IS NECESSARY .
Protective Gloves:CHEMICALLY RESISTANT PLASTIC OR RUBBER
Eye Protection:CHEMICAL WORKERS GOGGLES
Other Protective Equipment:EYE WASH AND SAFETY SHOWERS IN WORK
AREARECOMMENDED. USE PROTECTIVE HAND CREAMS TO PREVENT DEFAT OF
SKIN UPON EXPOSURE.
Work Hygienic Practices:WASH WITH SOAP AND WATER, REMOVE CONTAMINATED
CLOTHING BEFORE HANDLING FOOD OR SMOKING. DAILY SHOWERS
RECOMMENDED.
Supplemental Safety and Health
UNUSUAL FIRE AND EXPLOSION HAZARDS: HEAT. EMPTY CONTAINERS MAY EXPLODE
DUE TO RESIDUE. OBSERVE THIS MSDS. ALL METAL CONTAINERS MUST BE
GROUNDED OR BONDED DURINGLIQUID TRANSFER. SIGNS + SYMP OF OVEREXP
OSURE: CRACKING, DEFAT AND DERMATITIS ONPROLONGED EXPOSURE. HANDLE
STORAGE PRECAUT: WHERE VENTILATION IS ADEQUATE.

Chemical Properties

Boiling Pt:B.P. Text:232-380 F
Melt/Freeze Pt:M.P/F.P Text:N/K
Decomp Temp:Decomp Text:N/K
Vapor Pres:N/K
Vapor Density:HEAV AIR
Spec Gravity:1.3
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:N/K
Appearance and Odor:VISCOUS COATING WITH DISTINCT SOLVENT ODOR

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, ACIDS AND BASES
Stability Condition to Avoid:AVOID PROLONGED BREATHING OF VAPORS, SKIN
OR EYE CONTACT. STORE AWAY FROM HEAT, ELECTRICAL EQUIPMENT, SPARK,
OPEN FLAME.
Hazardous Decomposition Products:USUAL PRODUCTS OF COMBUSTION; CARBON
DIOXIDE, CARBON MONOXIDE, OTHER OXIDES, SMOKE, FUMES, ETC.
Conditions to Avoid Polymerization:WILL NOT OCCUR

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.